http://www.wwmt.com/news/calhoun_1350736___article.html/county_explosion.html
With over 160 ethanol plants in operation and 43 plants under construction the hazards of explosions and fires are omnipresent. Since July 2007, six reported ethanol plant explosions and fires have taken place in the United States. Last week the Anderson Corp. plant in Sheridan Township, Michigan exploded in the dryer area causing injuries and damage to the building.
Last December the distillers grain dryer was destroyed at the Pine Lake Corn Processors facility in Steamboat, Rock Iowa causing millions of dollars in damage. Luckily no injuries or fatalities occurred. The contractors at the Princess Anne, Maryland GreenLight Biofuels biodiesel plant were not so lucky less than two months ago when one fatality and one injury occurred after an explosion while adding a methane line during hot work.
Production and refining of ethanol and biodiesel is a new industry and will require that the owners and operators implement the same safety production procedures as the petrochemical refining industry
The current learning curve is now proving to be very costly in human lives and adverse economic effects to the community.
Ethanol Plant Explosions and Fires Google Map
Tuesday, July 1, 2008
Ethanol Plant Explosions Continue
Saturday, June 28, 2008
Bleak Picture of Plant Shutdowns
Here is an interesting snapshot of recent plant shutdowns in the United States. Many states have a web link that provides a listing of plant closings. The Worker Adjustment and Retraining Notification Act (WARN) offers protection to workers by requiring employers to provide notice 60 days in advance of covered plant closings and covered mass layoffs.
Employers are covered by WARN if they have 100 or more employees. A covered employer must give notice if an employment site (or one or more facilities or operating units within an employment site) will be shut down, and the shutdown will result in an employment loss (as defined later) for 50 or more employees during any 30-day period.
In many instances no warning of impending shutdown is provided if the company has less than 100 employees. With all the shutdowns occurring in the manufacturing sector the question arises of how a company can afford fire and explosion equipment in the prevention and mitigation combustible dust incidents.
The current combustible dust bill, HR 5522, Worker Protection Against Combustible Dust Explosions and Fires Act that is awaiting a hearing and vote in the Senate will require facilities that generate combustible dust to install fire and explosion prevention/mitigation equipment in accordance with the National Fire Protection Association combustible dust codes.
Congressional leaders that drafted the bill forgot to conduct a cost benefit analysis on the economic burden, which the legislation would impose on the manufacturing sector. In a recent article in the Washington Post (6/29/08), "5 Myths About the Death Of the American Factory,'' by Gilbert B. Kaplan, the author notes that in 2007, manufacturing jobs dropped below 14 million workers for the first time in over a half a century. This is a very disturbing trend and will only get worse as a barrel of oil approaches the $200 mark very soon.
Will a combustible dust bill also provide economic incentives like it does with the energy, agricultural, and other business sectors?
Plant Shutdowns 2008 Google Map
Tuesday, June 24, 2008
OSHA Combustible Dust Blame Game
Over the past year OSHA has constantly been negatively portrayed in the national headlines concerning workplace safety issues. Several weeks ago CBS 60 Minutes aired a segment, questioning whether current OSHA workplace health and safety regulations are adequate in protecting the nation's workforce from the hazards of combustible dust in the manufacturing sector.
Prior to this sensationalism in journalism , the House Education and Labor Committee through the leadership of Congressman George Miller (D-CA), drafted a crafty bill and held congressional hearings on combustible dust. Now after passage in the House, HR 5522, the Worker Protection Against Combustible Dust Explosions and Fires Act awaits hearings and a vote in the Senate and eventually the Presidents signature.
False Presumption
Through all the political hoopla and national media attention after the tragic sugar dust explosion at the Imperial Sugar Refinery on February 7, 2008 in Port Wentworth , Georgia many including the provider of content on this site have mistakenly concluded that OSHA is at fault in not providing sufficient combustible dust regulations. This is a false presumption when the facts of the complex combustible dust issue are revealed.
Its much easier for congressional leaders to place all the blame on OSHA instead of fully researching the cause and effect of combustible dust incidents. Unfortunately, the media picks up on this misinformation and political spin that is perpetuated in conjunction with the Imperial Sugar Refinery tragedy.
Local Issue not Federal
Hazards of combustible dust in the manufacturing sector is a municipal, state or regional issue, not a federal problem. Whenever there is a fire or explosion at a manufacturing facility with combustible dust involved, who are the first responders in extinguishing the fire? Of course, it's either the facility fire brigade or the local fire department.
What jurisdictional protections must be followed to ensure the life safety and structural integrity of commercial buildings is instituted and maintained? Yes, thats correct, building and fire codes. Since when has it been OSHA's responsibility to act as first responders to industrial fires and enforcement of fire codes?
Fire Codes
Currently states are either utilizing the International Code Council, International Fire Code (IFC) or the National Fire Protection Association, Uniform Fire Code(UFC) with references to the numerous NFPA combustible dust codes. Following the 2006 Dust Hazard Study, the Chemical Safety Board determined that many fire inspectors are not knowledgeable concerning the hazards of combustible dust that are referenced in the fire codes. Additionally, the CSB report discovered that the IFC or UFC fire codes adopted by several states had not been properly addressed in relation to combustible dust concerning commercial buildings.
Standard of Care
So is the fire code issue an OSHA problem? As enforcement action, OSHA currently utilizes the General Duty Clause for manufacturing facilities that violate workplace health and safety standards concerning combustible dust hazards. These standards in addition to current OSHA regulations include nationally recognized standards of care that is recognized by industry consensus through the American National Standards Institute (ANSI). Many of these standards of care include NFPA 484 (metal dust), NFPA 664 (wood dust), NFPA 61 (agricultural/food dust), NFPA 654 (combustible particulate solids), and NFPA 120 (coal dust).
Conclusion
The combustible dust bill, HR 5522, the Worker Protection Against Combustible Dust Explosions and Fires Act is redundant, which will require OSHA to incorporate the NFPA combustible dust codes that already are part of state fires codes. Furthermore, OSHA does not have enough financial resources and inspectors to inspect local manufacturing facilities with regularity like local jurisdictions do.
Georgia has taken the lead in requiring manufacturing facilities that generate combustible dust to register with the state. This action is similar to the European Union combustible dust ATEX directive requiring explosion protection document submittal from manufacturing facilities. Workplace protection from the hazards of combustible dust need not be controlled at the federal level.
Instead of the question,"Would combustible dust explosions occur if an OSHA comprehensive combustible dust standard was instituted?" The appropiate question would be, "Would combustible dust explosions occur if current fire codes followed the references to the NFPA combustible dust codes?"
Sunday, June 22, 2008
Government Safety Data Underreported
Last week the House Committee on Education and Labor convened a hearing on OSHA's underreporting of on-the-job injuries and illnesses. This was old news concerning the underreporting by governmental agencies. Crucial data concerning workplace safety is vital in promulgating policy and regulations to protect the worker. OSHA should not be singled out in problems collecting data. The Chemical Safety Board, an independent governmental investigative agency is also underreporting and undercounting safety data in the 2006 release of the Combustible Dust Hazard Study.
Chemical Safety Board Underreporting
Specifically, the Chemical Safety Board provided to the public and OSHA accident data from 1980-2005, which included 281 combustible dust fires and explosions. The disclaimer in the report states : the combustible dust incidents included are likely only a small sampling, as no federal or state agency keeps specific statistics on combustible dust incidents, nor does any single data source provide a comprehensive collection of all these incidents, nor does any single data source provide a comprehensive collection of all these incidents
Furthermore, information about small combustible dust incidents and near-misses is also generally unavailable. For instance, because incidents that cause no fatalities, significant injuries, or major fires may not be recorded in the OSHA and fire incident databases, the true extent of the problem is likely understated. Due to these limitations, the CSB does not represent the incident data as complete or error-free, and other compilations of dust explosion data are available.
Fact or Fiction
So how can policy be developed concerning general combustible dust standards if policymakers and legislators have no idea of the extent of the problem? A small sampling is just that, a sample. The problem of only relying on a sampling has been exasperated in the last four months since the Imperial Sugar Refinery explosion, where Congress and the national media is utilizing the CSB incomplete data as fact.
Nowadays, since the conclusion of the 2006 CSB Dust Hazard Study, information concerning recent combustible dust incidents can easily be found with a Google search on the Internet, through numerous online news reports. Yet the CSB still persists in undercounting combustible dust incidents and releasing this information to Congress and the media.
For example, in recent incomplete data provided to Congress, the CSB has reported an additional 70 combustible dust explosions and fires since the 1980-2005 period, for a total of 350 combustible dust fires and explosions in the last 28 years. This equates to one incident a month which is disjointed and skewed from the actual extent of combustible dust incidents that are occurring. For example, in the last four months over 50 combustible dust fires and explosions have taken place in the manufacturing sector.
Conclusion
The Chemical Safety Board is a governmental accident investigative agency and not a research agency. Over the past decade CSB has performed a superb job with it's limited resources in finding the root cause of chemical plant accidents, fatalities, and injuries. At the completion of it's investigations CSB provides free educational videos on lessons learned and investigative reports in the prevention of future incidents.
Daily intensive research concerning where and when combustible dust incidents are occurring in the nation's manufacturing sector is not the job function of CSB. Instead of all the political posturing that is now occurring in Congress concerning the passage of a comprehensive general combustible dust bill, more attention needs to be directed in seeking accurate information concerning the entire scope of industry combustible dust incidents.
Friday, June 20, 2008
Oregon OSHA Aknowledges Combustible Dust Hazard
http://www.oregonlive.com/business/index.ssf/2008/06/state_warning_of_dust_hazards.html
An interesting article was published today in the Pacific Northwest, written by veteran reporter Anne Saker of the Oregonian concerning Oregon OSHA and the hazard alerts the agency has sent out to approximately 2,500 manufacturing facilities in the state that handle combustible particulate solids which have the potential in generating combustible dust.
Combustible Dust Hazard Alerts is an excellent venue in bringing out an awareness concerning combustible dust. A follow-up to hazard alerts would be training concerning the complexities of combustible dust hazard recognition, hazard assessment, explosion hazard management, and understanding the numerous National Fire Protection combustible dust codes.
Other states can learn from example where Georgia is hosting a Fire Safety Symposium July 14-18 2008, which includes two days of training concerning combustible dust hazard recognition, which will be presented by Guy Colona, NFPA Vice President of Chemical Engineering and Amy Spencer NFPA Senior Chemical Engineer. Relying solely on good housekeeping is only one aspect of the solution in preventing and mitigating future combustible dust fires and explosions.
Wednesday, June 18, 2008
Georgia Leads in Preventing Combustible Dust Incidents
Georgia is now leading the nation in preventing future combustible dust incidents with a proactive program that requires all new and existing facilities that have operations involving the manufacturing, processing, and/or handling combustible particulate solids including manufacturing processes that create combustible dust to register with the state by July 1, 2008.
In addition to requiring facilities to register the Rules and Regulations for Loss Prevention Due to Combustible Dust Explosions and Fire were adopted by the state on March 7, 2008. These proactive measures provide a high level of safety awareness that will prevent and mitigate the occurrence of future combustible dust explosions and fires.
Georgia has adopted the International Fire Code, which makes reference to the numerous National Fire Protection Association combustible dust codes. Such as NFPA 654 Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids, which is available for free viewing and purchase on the NFPA website.
Georgia Fire Safety Symposium
While taking the lead, the Georgia Insurance and Safety Fire Commissioner, led by Commissioner John Oxendine has organized an educational program with the help of his professional staff, which is open to the public at the Georgia Fire Safety Symposium to be held at the Georgia Public Safety Training Center in Forsyth, Georgia on July 14-18 2008. Several educational tracks will cover engineering/building inspections, hazardous materials inspections, and fire safety education for fire professionals who work daily in the fire protection filed. The Symposium is the 37th annual event and is part of the Fire Education program that the state provides in accordance with the mandate of Official Code of Georgia Annotated Title 25, Chapter 2.
Combustible Dust Training
A special aspect of the Symposium will be two days of training concerning NFPA Standards on Dust Explosions on Hazards. Guy Colona, NFPA Vice President of Chemical Engineering and Amy Spencer NFPA Senior Chemical Engineer will be providing the presentations. Topics will include dust hazard characterization, background on lessons learned from previous combustible dust incidents, hazard recognition, hazard assessment, and explosion hazard management.
Participants attending the two days of combustible dust training in the 500 seat auditorium will gain an understanding of the numerous NFPA combustible dust codes that are referenced in the International Fire Code, which cover metals, agricultural and food products, wood, explosion venting, and explosion prevention systems.
Conclusion
The most unique aspect of the Symposium is that it is open to the public. So now all stakeholders who work, manage, or own manufacturing facilities that generate combustible dust from combustible particulate solids will have chance to gain an understanding of the complex subject concerning combustilbe dust. After June 20, 2008 tickets will cost $125.00, a very reasonable fee considering the scope and depth of the content.
Other states can now learn from Georgia's proactive example in also instituting measures in preventing and mitigating future combustible dust incidents in addition to providing combustible dust training to stakeholders in their region.
Resources:
2008 Brochure and Registration Forms
2008 Fire Safety Symposium Registration Form
RSS Feed Subscribe