Pages

Saturday, March 23, 2013

OSHA Fire Prevention Plans (FPP) & Hazard Assessments Ignored by Many

Figure 6. Number of Combustible Dust Related Violations

Figure 6. "Number of Combustible Dust Related Violations" OSHA Status Report on Combustible Dust National Emphasis Program (NEP) does not even note any combustible dust related violations for "1910.39 Fire prevention plans." How odd especially with requirements of a written plan on proper handling and storage procedures for hazardous materials, potential ignition sources and their control, and the type of fire protection equipment necessary to control each major hazard. In addition to procedures to control accumulations of flammable and combustible waste materials in conjunction with procedures for regular maintenance of safeguards installed on heat-producing equipment to prevent the accidental ignition of combustible materials.” I guess combustible dust is not considered a combustible waste material nor a hazardous material?

Congressional Proposed Interim Standard
Since OSHA 1910.39 Fire prevention plans have been ignored regarding combustible dust hazards they will now be included in the reintroduced combustible dust legislation "Worker Protection Against Combustible Dust Explosions and Fires Act of 2013," for an OSHA interim combustible dust standard. Elements in an interim standard will include:

(2)written program that includes provisions for hazardous dust inspection, testing, hot work, ignition control, and housekeeping, including the frequency and method or methods used to minimize accumulations of combustible dust on ledges, floors, equipment, and other exposed surfaces.

(3) Requirements for engineering controls, administrative controls, and operating procedures, including means to control fugitive dust emissions and ignition sources, and the safe use and maintenance of process equipment and dust collection systems and filters.

(4) Requirements for workplace inspection and housekeeping to prevent accumulation of combustible dust in places of employment in such depths that it can present explosion, deflagration, or other fire hazards, including safe methods of dust removal.

(6) Requirements to provide written safety and health information and annual training to managers and employees and their representatives, including housekeeping procedures, hot work procedures, preventive, predictive, and periodic maintenance procedures, common ignition sources, and lock-out, tag-out procedure.

NOTE: OSHA Fire Prevention Plans (FPP) only required if all of your employees evacuate immediately during a fire emergency (page 15 .pdf) or if one of these three host standards apply: CFR 1910.1047(h)(1)(iii): Ethylene Oxide, CFR 1910.1050(d)(1)(iii): Methylenedianiline, or CFR 1910.1051(j): 1,3-Butadiene.

Additionally no mention in the 2009 OSHA Status Report on Combustible Dust National Emphasis Program regarding combustible dust related violations in failure to have a certified written Hazard assessment 1910.132(d)(1) “The employer shall assess the workplace to determine if hazards are present, or are likely to be present...” Legislators did not forget that one either in the reintroduced combustible dust legislation with (1) Requirements for hazard assessment to identify, evaluate, and control combustible dust hazards.

OSHA Citations: Fire Prevention Plans (FPP) and Certified Hazard Assessments
Question is how can there be hundreds of combustible dust related incidents annually with over 500 in 2011 according  to a CDPI preliminary analysis of NFIRS data, if the required OSHA written Fire Prevention Plans (FPP) and certified Hazard Assessments plans are adhered to? Is it just a paper chase and stakeholders doing nothing more than filing the required written plans in the office file cabinet?

Federal OSHA citations for the period October 2011 through September 2012 in the Lumber And Wood Products industries, (Except Furniture) there was no Federal OSHA citations for 1910.39 - Fire prevention plans (FPP). With the over 500 ComDust related incidents in 2011 according to a preliminary NFIRS analysis, the Lumber And Wood Products industries experienced over 16% of the incidents. How can there be so many incidents yet in the same vein FPP is adhered to regarding regular maintenance of safeguards installed on heat-producing equipment to prevent the accidental ignition of combustible materials?

This observation is not meant to solely pick on the Lumber And Wood Products as there are dozens of other diverse industries handling combustible particulate solids. For example out of the over 12,700 Federal OSHA citations at 2,419 facilities in the manufacturing sector from October 2011 through September 2012, only two (2) Federal OSHA citations for 1910.39 - Fire prevention plans (FPP)  So the odds of receiving an OSHA citation for FPP in that time period was 0.016% out of the nearly 13,000 citations. 


Conclusion
The problem is intensified when viewing the OSHA website  on combustible dust hazards where, "Federal OSHA standards are mandatory; they include provisions that address certain aspects of combustible dust hazards. Some are industry-wide and others and industry-specific." No mention at all regarding certified written hazard assessment 1910.132(d)(1) nor any note of 1910.39 Fire prevention plans. Additionally, in the OSHA ComDust NEP  numerous OSHA CPL's listed in the reference section yet CPL 2-1.037, Compliance Policy for Emergency Action Plans and Fire Prevention Plans excluded. Wouldn't it be prudent for all global stakeholders to implement the protections of  hazard assessments and fire protection plans now instead of waiting for the results of proposed combustible dust legislation and regulations? 

 

Questions, Problems, Feedback? Please send email by clicking this link...Thanks

©Copyright 2008-2012. Combustible Dust Policy Institute
The information in http://dustexplosions.blogspot.com/ is not meant to be a substitute for the Code of Federal Regulations (CFR), Federal Register, and other OSHA documents, which should serve as the primary source of regulatory guidance. The information on this site should not be used in place of appropriate technical or legal advice related to your company's specific circumstances. Combustible Dust Policy Institute tries to provide quality information, but we make no claims, promises or guarantees about the accuracy, completeness, or adequacy of the information contained in or linked to this web site and its associated sites. Combustible Dust Policy Institute has no liability arising from or relating to the use, interpretation, or application of the information or its accuracy or inaccuracy. Copyright notice: All materials in this site are copyrighted by the Combustible Dust Policy Institute. No materials may be directly or indirectly published, posted to Internet and intranet distribution channels, broadcast, rewritten for broadcast or publication or redistributed in any medium without permission.