Spark Detection Systems-Podcast #4

Click Player for Podcast

Allen Wagoner, V.P. at Flamex and Bob Barnum, V.P Sales at GreCon Inc., discuss important aspects of spark detection engineering controls in lessening the probability and reducing the severity of combustible dust related fires and explosions at facilities.

Over the past year the Combustible Dust Policy Institute has found through media accounts over 130+ combustible dust related fires and explosions. Many of these incidents could have been prevented and mitigated with proper engineering controls as referenced in the NFPA Combustible Dust Standards. Concerning fire and explosion protection for process equipment, NFPA 654 lists several protection methods such as:

  • Oxidant Concentration Reduction
  • Deflagration venting
  • Deflagration pressure containment
  • Deflagration suppression
  • Dilution with non-combustible dust
  • Deflagration venting through a dust retention and flame-arresting device

In today’s podcast, we’ll discuss fire and explosion protection methods utilizing spark detection and extinguishment. Spark detection systems are used in dust collectors and pneumatic conveying systems to detect and extinguish sparks and embers.




Click Picture for Animation

Photo Credit: GreCon
The applications listed above are for example only. Qualified personnel must design suitable pneumatic conveying, electrical, and plumbing systems to local regulations, plant equipment and requirements. The drawings shown below may not meet the needs all facilities, but these drawings demonstrate how spark detection systems can be used in similar applications with the appropriate design

Resources

NFPA 654 Combustible Dust Standard
Flame Detection Tutorial-Sense Ware
Infrared Radiation

1 comment:

Anonymous said...

Facinating - Bob Barnum was great.

 

Questions, Problems, Feedback? Please send email by clicking this link...Thanks

©Copyright 2008-2012. Combustible Dust Policy Institute
The information in http://dustexplosions.blogspot.com/ is not meant to be a substitute for the Code of Federal Regulations (CFR), Federal Register, and other OSHA documents, which should serve as the primary source of regulatory guidance. The information on this site should not be used in place of appropriate technical or legal advice related to your company's specific circumstances. Combustible Dust Policy Institute tries to provide quality information, but we make no claims, promises or guarantees about the accuracy, completeness, or adequacy of the information contained in or linked to this web site and its associated sites. Combustible Dust Policy Institute has no liability arising from or relating to the use, interpretation, or application of the information or its accuracy or inaccuracy. Copyright notice: All materials in this site are copyrighted by the Combustible Dust Policy Institute. No materials may be directly or indirectly published, posted to Internet and intranet distribution channels, broadcast, rewritten for broadcast or publication or redistributed in any medium without permission.