Pages

Showing posts with label ATEX. Show all posts
Showing posts with label ATEX. Show all posts

Thursday, January 13, 2011

U.K Combustible Dust Fire with Metal Dust

“The fire was on the mezzanine floor in a hopper containing metal dust"
www.miltonkeynes.co.uk

OSHA needs to look at DSEAR and ATEX and include ComDust in the universe of potentially explosive atmospheres in the rulemaking process, which also includes flammable liquids, gases, vapors, and mists. Can't continue like the present situation in the USA with ComDust as a separate entity. Until then, the US Fire Administration will continue to ignore the fire and explosion hazards of ComDust with deficient incident reporting in the National Fire Incident Reporting System NFIRS 5.0

Friday, January 7, 2011

Combustible Dust Laboratory Testing Primer

Potential combustible dust fires and explosions in the manufacturing, non-manufacturing, and utility sectors is a global problem. Across international borders the occupational safety regulatory standards for addressing combustible dust fire and explosion hazards varies. In contrast, the laboratory equipment in evaluating the hazard for ignition sensitivity and explosion severity is uniform with minor differences in methodology. For example, the 20 liter sphere is utilized worldwide in obtaining vital information on the maximum pressure and deflagration index (Kst) of combustible dust.

An excellent depiction of a dust explosion shown in the high speed video, shot at 600 frames per second, with 1 gram of custard powder dispersed in a glass tube past a hot coil ignition source. The glass tube has a volume of 1.2 litres, providing an explosive dust concentration of approximately 830 g/m3. Notice how the explosion pressure wave drives the dust ahead of it and out of the tube and debris from the explosion - mostly pieces of unburnt powder - continue to fall for some time afterwards. The second video sequence shows the same quantity of custard powder being ignited, but viewed from above. Note the thin plastic film held across the tube opening that acts as an explosion relief vent.




The catastrophic Imperial Sugar Refinery dust explosion in 2008 reminded global stakeholders how devastating industrial dust explosions can be. Measuring the explosive properties of the material being handled is, of course, the essential first step to understanding the hazard. Michael Ward of Explosion Hazard Testing in the U.K. has written an educational and very useful guide to explain combustible dust testing and what the lab results tell us in terms of explosion prevention and protection options.

The main points that the guide discusses:

  • UK statistics for fire and explosion
  • What a dust explosion is and the terminology involved
  • What laboratory tests are available and how they are conducted
  • What they tell us about the fire and explosive properties of the material
  • What tests are considered mandatory under U.K. and and EU legislation

The dust testing guide can be downloaded for free here

Tuesday, January 12, 2010

OSHA Ventilation Standard Revise for Combustible Dust


Reviewing the recent OSHA Combustible Dust NEP status report (Figure 6) illustrates that 90% of the citations for combustible dust arose from OSHA General Industry Standards. Approximately 10% of the citations were General Duty Clause citations where a majority of examples were for ventilation such as ductwork, dust collectors, and other aspects of the dust collection system used in ventilation. (pages 7-10 of 12 page .pdf)

The current OSHA General Industry Ventilation Standard 29 CFR 1910. 94 includes elements that address dust hazards in abrasive blasting, grinding, polishing, and buffing operations. Problem is, the Ventilation Standard originates more from an industrial hygiene viewpoint, where attention is directed towards respiratory hazards such as silica sand inhaled during blasting operations. What about combustible dust fire and explosion hazards from inadequate ventilation throughout the manufacturing sector?

Local Exhaust Ventilation
A key aspect in the fire triangle in reducing the possibility of a combustible dust fire or explosion is to remove the combustible dust fuel load. Good housekeeping alone will not completely remove the dust fuel load in most manufacturing processes, so dilution ventilation or local exhaust ventilation (LEV) must be utilized. Local exhaust ventilation (LEV) is the most effective in reducing explosive combustible dust concentrations.

Local exhaust ventilation (LEV) includes four major components: exhaust hood, ductwork, fan/ motor, and dust collector. The system must be properly designed and maintained so as to prevent and mitigate possible combustible dust related fires and explosions. Many of the combustible dust related fires occur or progress into the ventilation system. So it is extremely important that spark detection/flame suppression, abort gates, and explosion ventilation be incorporated in the industrial ventilation system.

General Industry Standards
The OSHA General Industry Ventilation Standard 1910.94(a)(2)(iii), does note that for abrasive blasting, the principles set forth in the National Fire Protection Association Explosion Venting Guide, NFPA 68-1954 be adhered to. What about other manufacturing processes where flammable or explosive dust mixtures may be present? There is a disconnect in many other General Industry Standards in not addressing combustible dust hazards such as in Hazard Communication, Housekeeping, and PPE. It's odd that Powered Industrial Trucks and Hazardous (Classified) Locations General Industry Standards address combustible dust, yet the majority of other General Industry Standards do not.

A proposed separate combustible dust standard does not address the antiquated OSHA General Industry Standards where many of the standards are from an industrial hygiene standpoint that fails to comprehensively address fire and explosion hazards concerning occupational safety. The Ventilation Standards in the maritime, construction, and general industry is an excellent example of this weakness.

For example, ventilation fire hazards in spray finishing are addressed in regards to solvent vapor there is the requirement 1910.94(c)(6)(ii) to dilute solvent vapor to at least 25 percent of the lower explosive limit of the solvent being sprayed. What about minimum explosive concentrations (MEC)/lower explosive limit (LEL) for combustible dust that is captured in the industrial ventilation system that are also possible fire and explosion hazards thoughout the manufacturing sector?

Potentially Explosive Atmosphere

Until OSHA recognizes that combustible dust is a potentially explosive atmosphere like in the above example for solvent vapors there will be a weakness in the Ventilation Standards that is mostly directed towards industrial hygiene. An excellent example where our international trading partners do understand that combustible dust poses an explosive atmosphere like flammable vapors, gases, and mists is the U.K DSEAR and EU ATEX Directives

OSHA cannot continue to address Industrial Ventilation as the
most important engineering controls solely from an industrial hygiene standpoint. Industrial safety is just as important and must be on the flip side of the coin. The OSHA Salt Lake Technical Center(SLTC), which edited the informative and educational OSHA Ventilation Health and Safety Topics page should know better. Especially when SLTC is conducting all the testing for combustible dust ignition sensitivity and explosion severity.

U.S. Bureau of Mines

Over two decades ago Martin Marietta Laboratories and Marcom Associates, Inc. under contract from the U.S. Bureau of Mines (USBM closed in 1995 and transferred to NIOSH in 1996), prepared an excellent 220 page document, "Dust Control Handbook For Mineral Processing." The educational content was mostly centered on respiratory hazards concerning industrial hygiene in the mineral processing industry.

Many of the excellent chapters are applicable to the design and maintenance of industrial ventilation so as to minimize combustible dust fire hazards. In addition to the resource being located on the OSHA Safety and Health Topic Silica, Crystalline pages it should be cross-referenced on the OSHA Safety and Health Topic Ventilation Additional Information page.

Conclusion

In conclusion from reviewing the OSHA Combustible Dust NEP status report it appears that too much emphasis is being directed toward the General Duty Clause. Especially when over 30 percent of the report provides examples of General Duty Clause combustible dust citations where a majority of these citations are for industrial ventilation issues. What the ComDust NEP status report failed to emphasize, was the 90% of citations arose from General Industry Standards. Powered Industrial Trucks was not even included in Figure 7 of the report. Many of these antiquated General Industry Standards have not come to terms with combustible dust fire and explosion hazards from an industrial safety standpoint.

A separate combustible dust standard will provide many with a warm and fuzzy feeling but does not address an alternative regulatory approach in revising the current General Industry Standards so as to comprehensively come to terms with the 21st century occupational safety fire and explosion hazards in the workplace.

Resources
Designing Dust Collection Systems by Gary Q. Johnson-Workplace Exposure Solutions

Wednesday, January 6, 2010

Gas, Vapour & Dust Explosion Hazards -ATEX Education

Continuing Professional Development

Back to Fire CPD

Gas, Vapour & Dust
EXPLOSION HAZARDS
Protection, Mitigation and Prediction

Monday 22 - Friday 26 March 2010

10% discount for IFE Members - CPD 33hrs


Programme

Course Leaflet (PDF)

Registration Form


Course format

The Explosion Hazards short course will be delivered by a team of practitioners and academics, all experts in their particular fields of contribution. The course has been extensively revamped in response to the positive feedback from participants and the continuing interests and rapid developments in the field.

Oral presentations will concentrate, where appropriate, on the implications and practical application with example calculations of the research findings (so please bring a calculator). Detailed course notes will provide comprehensive coverage of research methodologies and results.

Contact

For a full programme and registration form by email or post, contact:
Rachael Lawson, CPD Course and Events Co-ordinator,
CPD Unit, Faculty of Engineering,
School of Civil Engineering, Room 209,
University of Leeds, LEEDS, LS2 9JT, UK.
Telephone: + 44 (0)113 343 8104 Fax.: + 44 (0)113 343 2511
Email: cpd@engineering.leeds.ac.uk

This is the sort of courses that we need more of in the United States in understanding that combustible dust poses a potentially explosive atmosphere like flammable gaes, vapours, and mists (ATEX). All the rules and regulations in the world is only cursory until all stakeholders understand that combustible dust explosions and flash fires are propagating events similiar to vapor cloud flash fires and explosions. Can one differentiate the differences in the catastrophic results of overpressure, thermal radiation, and ensuing deadly projectiles between a dust explosion and vapor cloud explosion?

http://fengsrv1.leeds.ac.uk/cpd/documents/Leaflet_093.pdf

Posted via web from ComDust

Thursday, November 12, 2009

Forklift Operations in Potentially Explosive Atmospeheres

I'd like to share this post that was authored by Robert Zuiderveld, General Manager at Pyroban Corp in the ComDust discussion group.

The recent Forkliftaction.com article by contributing editor Tom Andel,"Keeping forklifts out of explosive situations," clearly illustrates that the majority of stakeholders do not understand the complexities involved in or consequences resulting from operating non- compliant powered industrial equipment in potentially explosion hazardous areas. Even though I appreciate the attention the article is putting on the issues at hand I am concerned with some in the information and statements published in the article.

CAL-OSHA

According to the OSHA IMIS citation and violation data, CAL-OSHA has not written a single OSHA 1910.178. C01 or C02 citation between Jan 1, 2003 and the present. Yet according to the NFIRS data approximately 432 fires were started by powered industrial equipment in California between 2003 and 2007.

As a matter of fact OSHA regions 9 and 10 (entire West Coast region) experienced approximately 600 and 742 fires respectively (according to the NFIRS), while only one (1) OSHA 1910.178. C01 citation was written (Nevada in 2003) between Jan 1, 2003 and the present in both regions.

I can only wonder why CAL-OSHA publishes an article about equipment fire and explosion safety while they appear to have completely ignored enforcement of the issue for at least 6 years?

Lack of Ex Hazard Awareness
I also have to question these statements:

“The problem is it’s not easy or cheap to find replacements,” he says. “For example, an electric forklift designed for heavy use in an outdoor location is not easy to come by. A number of my clients are concerned because they’ve been cited for having unapproved forklifts in their outdoor locations. We’re not sure what the fix is but we know it will be pretty expensive. You can’t use gasoline fired engines because of the various ignition sources. Now they’re coming after diesel.”

Availability of equipment:
The industry offers EX solution for diesel and electric powered trucks which are compliant with ATEX codes and regulation and can and may be safely operated in US facilities handling flammable materials. They are pretty easy to find for anybody with access to a computer, the Internet and the ability to type in “explosion proof forklift truck” in a Google, Yahoo or Bing search engine.

Cost of the equipment:
Yes, explosion protected equipment is more expensive than conventional equipment types. However when you compare their price to the cost involved in injuries, fatalities or adverse economic effects after an fire or explosions incident, there really is not that much money difference. Besides that it appears that litigious nature of society is eager to put a price on a human life, so I would like to challenge anyone to come up with putting a cost on a human life which lower than the cost of an EX forklift truck.

Equipment approvals:
It is true that UL approved EX diesel equipment is hard to find, for that matter none existent. This is due to the fact that UL never develop HAZLOC codes, regulations, construction specification or testing procedures for IC powered industrial equipment used in explosion hazardous areas.

ATEX ATmosphères EXplosibles
OSHA however has not objected to the use of ATEX compliant conversion in explosion hazardous areas in US as long as it passes a hazardous equivalency test and evidence of certification can be provided. OSHA has not cited companies using internationally certified EX equipment because of two little know OSHA enforcement facts:

1. OSHA has the “burden of proof” that equipment is unsafe
2. OSHA will allow the use of international certified equipment if not US certified alternative exists

ATEX certified solutions are available to industry and they meet both criteria, especially when it comes to diesel powered explosion proof equipment.

OSHA Powered Industrial Trucks
And these equipment type suitability/approval claims:

“OSHA’s diesel designations include DS (with safeguards to the exhaust, fuel and electrical systems) and DY (with all the safeguards of DS units plus temperature limitation features). The only forklifts approved for Division 1 hazardous locations are electric-powered, designated EX (with safeguards for use in atmospheres containing flammable vapors or dusts). DS, DY, EE (enclosed electrical equipment) and EX are approved for Division 2.”

Crucial Mistake
Unfortunately OSHA is making a commonly made crucial mistake by implying the suitability of UL approved DS, DY and EE equipment types for use in explosion hazardous areas. UL does not test, certify or approve the use of these equipment types for use in explosion hazardous areas. If equipment is tested and certified for hazardous areas, the appropriate hazardous area classification will be shown on the ID tag of the equipment. If contact your equipment OEM or UL for a written statement of the hazardous area suitability of the of DS, DY and EE type you will be able to quickly verify this info.

Authority Having Jurisdiction:
Keep in mind Lawyers are not listed in the NEC/NFPA standards as an Authority Having Jurisdiction (AHJ) and their technical judgment of equipment suitability or code interpretation is completely irrelevant.

More interesting to the law factor is the actual US product law:

S.3014
To amend title 18 of the United States Code to penalize the knowing and reckless introduction of a defective product into interstate commerce. IN THE SENATE OF THE UNITED STATES

September 7, 2000
Mr. SPECTER introduced the following bill; which was read twice and referred to the Committee on the Judiciary.

A BILL To amend title 18 of the United States Code to penalize the knowing and reckless introduction of a defective product into interstate commerce. Be it enacted by the Senate and House of Representatives of the United States of America in Congress assembled.

SECTION 1. DEFINITIONS.
(a) A 'defective' product is one with a flaw in design, manufacture, assembly, or instruction which renders the product dangerous to human life and limb beyond the reasonable and accepted risk associated with such or similar products lacking such a flaw.

(b) To 'introduce' a product into the stream of interstate commerce is to manufacture, assemble, import, sell, or otherwise produce or transfer the product in question.

(c) 'Person' means the employees of any corporation, company, association, firm,
partnership, or other business entity.

(d) 'Serious bodily injury' means bodily injury which involves--
(1) a substantial risk of death;
(2) extreme physical pain; or
(3) protected or impairment of the function of a bodily member, organ, or mental faculty.

SEC. 2. ENACTMENTS.
(a) A person who in gross deviation from a reasonable standard of care introduces into interstate commerce a product known by that person to be defective which causes the death of any individual shall be guilty of murder in the second degree and shall be imprisoned for a term of up to fifteen years.

(b) A person who in gross deviation from a reasonable standard of care introduces into interstate commerce a defective product which causes serious bodily injury to any individual shall be imprisoned for a term of up to 5 years.

Post By
: Robert Zuiderveld

Resources:

OSHA Powered industrial trucks. - 1910.178

NFPA 505: Fire Safety Standard for Powered Industrial Trucks

Contact Info
Robert Zuiderveld-General Manager at Pyroban Corp.
T: +1-973-748-0760
F: +1-973-842-0508
E: salesusa@pyroban.com


Thursday, November 5, 2009

OSHA Flammable Liquid, Gas, and Vapor Regulation Next?

http://www.localnews8.com/Global/story.asp?S=11442416

"Fire breaks out at oil refinery north of SLC"

Seems like a week doesn't go by that one doesn't hear about another facility exploding or catching on fire due to flammable liquids, gases, or vapors. Since 2003 the Chemical Safety Board has investigated nearly two dozen of these incidents. Now with this recent incident hitting the news wire, CSB will also investigate another refinery fire in Salt Lake City. So is it time now for a separate OSHA Flammable Liquid, Gas, and Vapor Regulation next? After all, a separate OSHA combustible dust regulation is in the works.

Explosive Atmospheres
Potentially explosive concentrations of gas, vapor or mist in the air, also includes concentrations of dust in the air. Amazingly, the explosive effects are all the same with overpressure, thermal radiation, and ensuing projectiles. In fact a vapor cloud explosion is a propagating explosion like a dust explosion, where there is a pressure wave and flame/reaction front in both. The main difference between vapors and combustible dust is a lower ignition sensitivity (MIE) with vapors.

No I guess it wouldn't make sense to have a separate OSHA Flammable Liquid, Gas, and Vapor Regulation. That makes as much sense as having a separate OSHA combustible dust regulation. What needs to be done instead is for all stakeholders to acknowledge that combustible dust is a potentially explosive atmosphere like all the rest. A separate dust regulation only further deviates from the issue that what we got here is one nasty hombre that needs the same respect as all the other explosive atmospheres. Check out elements of the ATEX directive from our global trading partners in the EU to get an idea of how the wheel does not need to be reinvented.

Dust ANPRM -Physical Properties
Acknowledging combustible dust as a potentially explosive atmosphere will go a long way in fixing the broken OSHA HazCom standard. The recent combustible dust ANPRM did not even mention the physical properties aspect that CSB found was deficient in the 140 MSDS's they surveyed in the 2006 Dust Hazard Study. It's like how would the raw product manufacturer of milk have any idea that his product had inherent explosive severity and ignition sensitivity characteristics? Midstream in the life-cycle at the milk powder plant with the spray dryers is an entirely different situation.

We all have heard it, in all the recent press releases over the past 20 months that a separate dust regulation will prevent dust explosions. Well of course if you shut down the entire manufacturing sector you would prevent primary explosions. But its not the primary explosions that resulted in the catastrophic events of Imperial Sugar and the devastating toll of the three dust explosions in 2003. It was the secondary explosions fueled by poor housekeeping. Simply remove the fuel load and you won't have a secondary dust explosion. In contrast, primary dust explosions will never be totally prevented, only the severity and probability reduced with appropiate layers of protection.

Majority Incidents-Fires
Last year there was over 150 combustible dust related fires and explosions in the manufactruing, non-manufacturing, and utility sectors. Not counting Imperial Sugar, the human toll was minimal in comparison to any other industry. Any fatality or injury is one too many. Yet, the severity of injuries would of even been less if the workers had donned flame resistant clothing. Over 80% of the incidents in 2008 were combustible dust related fires not explosions. Most incidents barely get notice in the news because thankfully there's no fatalities or injuries, only minor economic damage to the facility.

All combustible dust related fires and explosions need to be addressed in the realm of occupational health and safety. Already dusts are mentioned in several OSHA general industry regulations. So lets stop fooling around and get the specific wording "combustible dust" in the rest if the OSHA general industry regulations like is done with flammable liquids, gases, and vapors.

Failure to Communicate
It's frustrating to see all the mention of the issue solely on the process materials (dust). What about process conditions and process situations? You can't be identifying, evaluating, and controlling the hazard without recognizing the entire triad. Sort of reminds me of the scene in the 1967 movie, "Cool Hand Luke," when the Captain tells Luke, ""What we've got here is...failure to communicate." In this case of dust, there is a need to communicate the entire risk in the national policy making dialogue.

The issue of combustible dust incidents is a process situation where a majority of facilities have similiar processes that include bulk storage, material transfer, pnuematic conveying, duct systems, pressure relief devices, material feeding devices, belts, drives, conveyors, air material separators, mixers/blenders, dryers, etc. The only difference is the type of process materials (dust) spread out over 400 national industries in the industrial sector. A Hybrid Process Safety Management (PSM) standard for combustible dust is in order. Why keep trying to reinvent the wheel when a majority of PSM elements already are incorporated in the National Fire Protection Association combustible dust standards?

But again why not? Maybe a separate OSHA Flammable Liquid, Gas, and Vapor Regulation and another separate OSHA combustible dust regulation makes more sense. Just my two cents.

Tuesday, October 20, 2009

Hot Work Adjacent to Explosive Atmospheres



Initially when reading the recent news account of a worker that ignited flammable vapors causing an explosion while using a hand grinder to cut bolts embedded in the floor, it had not donned on me the gravity of the situation. That was until Jeffrey C. Nichols, President, South East Fire Prevention, Inc sent me an email this morning reminding me it could also happen with combustible dust. That is true, combustible dust provides explosive atmospheres just like flammable gases, vapors, liquids, and mists.

In many instances combustible dust related fires and explosions have occurred due to hot work providing the ignition source. One news account mentions that there was a sign adjacent to work area, that the area was hazardous. The same sort of warning signage should also be in areas where combustible dust is generated. In the EU, the ATEX directives have a provision for such signage. In the USA an OSHA combustible dust rulemaking is in the process and hopefully a provision of warning signage in communicating the risk from combustible dust explosions or fires will be included in the combustible dust rulemaking.

It is essential that prior to any hot work being conducted that a job hazard analysis be conducted evalauting the risk from potential fires and explosion. This ensures that a hot work permit includes all the potential ignition and fuel sources in managing the risk.

Thursday, October 15, 2009

Combustible Dust Hazards Lacking in Safety Data Sheets

In the global workplace, identifying and evaluating the risk from combustible dust related fires and explosions supposedly begin with the information provided on Safety Data or Material Safety Data Sheets (SDS/MSDS). These essential documents provide essential hazard identification, information on ingredients, first aid measures, fire-fighting procedures, handling and storage information, exposure controls/personnel protection, physical and chemical properties, etc.

Yet vital combustible dust physical characteristics of ignition sensitivity and explosion severity is lacking in a majority SDS’s. So how do stakeholders manage the risk in the workplace if important fire and explosion data is lacking?

Physical Fire and Explosion Hazards
An important development in hazard communication
amongst international trading partners is the United Nations Globally Harmonized System of Classification and Labelling of Chemicals (GHS). This system provides a universal method of communicating the potential health and physical hazards that chemicals pose in the workplace, during transportation, or consumer usage of chemical products. Yet unfortunately, harmonization in communicating the physical and chemical hazards of combustible dust is also deficient in the newly implemented United Nations GHS.

Additionally a major problem arises with materials that are not chemicals, such as wood, paper, food, etc that are not included in the GHS Safety Data Sheet hazard communication protocol. How are the physical hazards of potential combustible dust related fire and explosions suppose to be communicated to the workplace from these non-chemical substances? The problem is intensified with the requirement that the raw product manufacturer or importer must provide the physical property data in the initial preparation of the SDS.

Life-cycle Hazard Awareness
This is great at the initial stage of a raw product’s lifecycle. But what about later on in the life-cycle when a product manufacturer utilizes the raw product in the production process? The production process handles the combustible particulate solid and generates combustible dust in operations
such as cutting, grinding, polishing, crushing, conveying, mixing, sifting or screening of materials.

Now all of a sudden the physical properties have changed from a raw bulk product with a minimal hazard to a substance that provides a potentially explosive atmosphere under the right conditions. All that is needed for a dust explosion in addition to the basic fire triangle is a rendezvous with confinement and suspension .Understanding the parameters to initiate a combustible dust flash fire or dust explosion is where the SDS should come into the picture in managing the fire and explosion risk, but unfortunately does not.

Global Harmonization Deficiency
Back in April 2009, the USA Occupational Health and Safety Administration (OSHA) submitted a working document to the United Nations Committee of Experts on the Transport of Dangerous Goods on the Globally Harmonized System of Classification and Labeling of Chemicals. The document requested that the
Sub-Committee of Experts on the Globally Harmonized System of Classification and Labelling form a conference committee in developing classification criteria for combustible dusts in the Safety Data Sheets.

Currently GHS recognizes combustible dust is a hazard by identifying dust in the SDS. Solely identifying is not sufficient enough. The global workplace needs additional information such as guidance in fire-fighting measures, exposure controls/personnel protection, handling/storage, physical and chemical properties, etc.

Explosive Atmospheres
Additionally combustible dust needs to be
classified like flammable liquids and gases, which also can present an explosive atmosphere in the global workplace. In the EU, the ATEX Directives (Appareils destinés à être utilisés en ATmosphères EXplosibles) already recognizes the explosive nature of combustible dust that have the same explosive severity as vapor cloud explosions. Yet communicating the risk amongst international trading partners is another story through the GHS Safety Data Sheets.

In the United States recognition of the fire and explosion hazards from combustible dust that have the potential of an explosive atmosphere is not on the same level of awareness as the ATEX Directives in the EU. Currently in the USA, there is no occupational health and safety regulation that specifically references combustible dust in the industrial setting. In contrast there is an OSHA Grain Facility Standard that was implemented back in the 1980’s that addresses combustible dust hazards in grain mills, feed mills, etc.

Rulemaking Process
Following the catastrophic 2008 Imperial Sugar Refinery dust explosion in Port Wentworth, Georgia OSHA began taking
enhanced measures in addressing combustible dust in the manufacturing workplace. Currently OSHA is in a general industry combustible dust rulemaking process. An undisclosed source says that OSHA will announce next week in the Federal Register the Advanced Notice of Proposed Rulemaking (ANPRM) where stakeholders can comment in the development of the proposed general industry regulation.

On another front, concerning hazard communication, OSHA is proposing to modify its existing Hazard Communication Standard (HCS) that includes Materiel Safety Data Sheets to conform with the United Nations’ (UN) Globally Harmonized System of Classification and Labelling of Chemicals (GHS). Two weeks ago OSHA issued its proposed rule in the Federal Register concerning harmonization of its current Hazardous Communication System with GHS and will seek comments from stakeholders for a ninety day period.

In addition to proposing to the United Nations committee that combustible dust be classified in the GHS Safety Data Sheets its also seeking comments from stakeholders in the USA whether the interim coverage of combustible dust as an unclassified hazard in the GHS SDS is sufficient in communicating the risk throughout the workplace. Hopefully stakeholders will provide OSHA with a plethora of comments on this very complex issue of combustible dust related fires and explosion in the industrial workplace.

Conclusion
Presently all global manufacturing facilities are at risk with the deficient ignition sensitivity and explosion severity information not included in the Safety Data and Material Data Sheets. The only alternative
in properly managing the risk proactively would be for plant owners and managers to have their combustible dust tested for minimum ignition temperature (MIT), minimum ignition energy (MIE), minimum explosive concentration (MEC), explosion severity, volume resistivity, etc. Solely relying on physical fire and explosion hazard data in the SDS or MSDS that the raw product manufacturer or importer provided at the top of the lifecycle is an accident waiting to happen.

Resources

Classification and Labeling of Chemicals (GHS).

Working Document ComDust GHS

ATEX directive
Hazard Communication Guidance ComDust
OSHA HazCom Proposed Rule GHS

Thursday, April 17, 2008

ATEX: ATmosphères EXplosibles

It's odd that our major global trading partners have instituted proactive controls in the protection of the workplace and personnel from the hazards of combustible dust incidents. Yet here in the United States under the direction of the current OSHA management there is a wait and see attitude with the idea that additional studies must be completed before further OSHA standards can be instituted concerning the hazards of combustible dust.

With innovative leadership, OSHA could instead develop a program similar to the ATEX standards that have been implemented since 2003 in Europe. Here is an excellent resource that will provide industry with guidance in developing a proactive combustible dust preventive and mitigative program. Browse the articles provided by Epsilon:

Web Based Articles

 

Questions, Problems, Feedback? Please send email by clicking this link...Thanks

©Copyright 2008-2012. Combustible Dust Policy Institute
The information in http://dustexplosions.blogspot.com/ is not meant to be a substitute for the Code of Federal Regulations (CFR), Federal Register, and other OSHA documents, which should serve as the primary source of regulatory guidance. The information on this site should not be used in place of appropriate technical or legal advice related to your company's specific circumstances. Combustible Dust Policy Institute tries to provide quality information, but we make no claims, promises or guarantees about the accuracy, completeness, or adequacy of the information contained in or linked to this web site and its associated sites. Combustible Dust Policy Institute has no liability arising from or relating to the use, interpretation, or application of the information or its accuracy or inaccuracy. Copyright notice: All materials in this site are copyrighted by the Combustible Dust Policy Institute. No materials may be directly or indirectly published, posted to Internet and intranet distribution channels, broadcast, rewritten for broadcast or publication or redistributed in any medium without permission.