Combustible dust related fire in a sawdust hopper area of origin at a NAICS: 321212 Softwood Veneer and Plywood Manufacturing facility in California resulting in two injuries. Ironically the OSHA Combustible Dust National Emphasis Program (Reissued) does not recognize Softwood Veneer and Plywood Manufacturing facilities as having a potential for Combustible Dust Explosions/Fires in Appendix D-1 nor D-2 of the NEP.
With the commonality of hoppers throughout all manufacturing sectors having combustible dust fire and explosion hazards it is time OSHA comes to the realization that the ComDust NEP is ineffective in providing stakeholders a proactive awareness of combustible dust workplace hazards. Wouldn't it be prudent for OSHA to revise the current static ComDust NEP document in accordance with reality? Solely targeting specific processes while ignoring others is not the answer as we see in this unfortunate incident and many other countless NAICS Non-NEP fires and explosions. Time is way overdue in providing much needed awareness, outreach, and education throughout the entire gamut of the industrial sector.
These combustible dust related fires are a regular occurrence in the manufacturing and non-manufacturing sectors globally. In most instances they are non-consequential with no fatalities, injuries, or property damage. Best industry practice in minimizing the probability and severity of future incidents can be found in the recently revised edition of NFPA 664.
Showing posts with label NFPA 664: Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities. Show all posts
Showing posts with label NFPA 664: Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities. Show all posts
Tuesday, November 13, 2012
Two Injured Combustible Dust Related Fire in California
Thursday, December 31, 2009
School Fire causes $300k damage in Wood Shop
fire began when a spark from a circular saw being operated by a staff member ignited sawdust and set fire to the extractor system.
via abc.net.au
Globally it is a regular occurrence at educational institutions of fires occurring in the dust collector systems. NFPA 664: Standard for the Prevention of Fires and Explosions in Wood Processing and Woodworking Facilities is an excellent resource in providing guidance of best engineering practices for minimizing the severity and reducing the consequence of future incidents. Would a spark detection and flame suppression system minimized the $300,000 of damage in this incident? News Video
Posted via web from ComDust